This Schneider Electric Homeline package combines a 100 A, 30-space/60-circuit single-phase main breaker load centre with 14 plug-in Homeline breakers, giving contractors a job-ready panel for residential new builds, renovations and service upgrades. The plug-on neutral design and fully distributed neutral bars speed up installation and keep panel wiring tidy, while 30 spaces leave room to expand up to 60 circuits as the job grows.
Key Features
- Complete Panel Package: One part number covers the load centre plus the most common branch-circuit breakers, ten 1-pole 15 A, two 1-pole 20 A, one 2-pole 30 A and one 2-pole 40 A, so crews spend less time pulling parts.
- Plug-On Neutral Design: Fully distributed neutral bars accept plug-on neutral breakers without pigtails, cutting installation time and keeping the gutter clean for inspection.
- Room to Expand: 30 spaces support up to 60 circuits using tandem breakers, so the panel can grow with additions, basement finishes and future loads.
- Service-Entrance Approved: The factory-installed 100 A main breaker is approved for service-entrance use, covering panel replacements and new services with a single package.
- 22 kA Short-Circuit Rating: The main breaker carries a 22,000 A maximum short-circuit current rating, providing added fault-current headroom on residential services.
- Flexible Installation: Multiple breaker knockouts and top-or-bottom mains feed simplify rough-in, and the shielded bus helps protect the installer during wiring.
Specifications
| Brand | Schneider Electric Homeline |
| Package Contents | 100 A main breaker load centre plus 14 plug-in breakers (10 × 1P 15 A, 2 × 1P 20 A, 1 × 2P 30 A, 1 × 2P 40 A) |
| Mains Rating | 100 A, factory-installed main breaker |
| Spaces / Circuits | 30 spaces / up to 60 circuits with tandem breakers |
| Electrical Rating | Single-phase, 3-wire, 120/240 V |
| Main Short-Circuit Rating | 22 kA |
| Main Wire Size | #6–2/0 AWG |
| Branch Breaker Wire Range | 14–8 AWG (15 A–30 A breakers); 8–2 AWG (40 A breaker) |
| Branch Breaker Ratings | Plug-in mounting; HACR rated |
| Service Entrance | Approved |
| Enclosure | Type 1 (NEMA 1) with combination cover; ground bar included |
| Mains Feed | Top or bottom entry; multiple knockouts |
| Certifications | CSA certified load centre and breakers |
| Location Rating | Indoor use only |